• +44 7985 319 479
  • Monday - Saturday 10 AM TO 5 PM
ECU Master PMU
  • SKU: PMU-NODATA
  • Availability: in stock Many in stock Out of stock You can purchase this product but it's out of stock

ECU Master PMU

£958.80
    DESCRIPTION

    ECU Master PMU

    State of the art product from ECUMASTER top of the modern power distribution technology.
    Intelligent power distribution simplify your wiring and provide functionality not possible for traditional wiring 
    One of the main advantages of the PMU is continuous current sensing and self-resetting functionality if current exceeds the defined level. All output state, voltage and current information can be logged and transmitted via CAN bus to dash displays to inform drivers of potential problems.

    An additional advantage of the PMU system is the ability to define logic for controlling outputs. This is done with data from analogue input channels or CAN bus data, and math operations can be defined for each channel. The PMU is also equipped with LED indicators to show the status of each output.

    With use of CAN bus keypads or steering wheel switches, all wiring is vastly simplified and lightened.Two unique features are the inbuilt accelerometer and gyro for logging and “inertia switch” in case of accident.
    System is designed for easy integration with our range of accessories. 
    Key pads 6 Key , 8 KeyCan switch board


    Please note for communication to PMU, CAN to USB interface is required

    SPECIFICATION

    GENERAL

    Temperature range AECQ100 GRADE1 (-40 to +125˚C)
    CPU 32 bits automotive, 90MIPS
    Reverse polarity protection Yes, internal
    Operating voltage 6-22V, immunity to transients according to ISO 7637
    Enclosure IP 65, bespoke CNC machined aluminium
    Size (mm) and weight(g) 131x112x32.5, 345g
    Connectors 1 x 39 Automotive connector,

     

    1 x M6 stud for battery connection

    PC communication CAN (ECUMASTER USBtoCAN, PEAK CAN, KVASER)

    OUTPUTS

    High current outputs 10 x 25A(cont.), 6 x 15A(cont.) with overcurrent and overheating protection. Outputs may be paired to increase continuous current capability. Current and voltage is measured for each output
    Total current output 150A continuous
    Output current control step 100mA
    Wipers output Dedicated output with wiper braking feature
    +5V Monitored 5V, 500mA output for powering external sensors.

    INPUTS

    Analog inputs 16 inputs, 10 bit resolution, 0-5V (protected), with software selectable 10K Ohm pullup and pulldowns
    CAN Keypads 2 x Ecumaster keypads (4, 6, 8, 12 keys)

    OTHER

    Output state indication 16 bicolour LEDs
    Accelerometer/Gyroscope 3D accelerometer with 3D gyroscope for logging and crash detection
    Real time clock Yes, super capacitor for backup power (up to 3 days)

     

    CAN BUS

    CAN interface 2 x CAN2.0 A/B
    CAN standard CAN2.0 A/B – 125, 250, 500, 1000 kbps
    Input/output stream User defined with bit masking,

     

    up to 100 input messages

    LOGGING*

    Logging memory 256 Mbytes
    Logging speed Variable, defined per channel, up to 500Hz

    FUNCTIONS

    Logical operators AND, OR, NOT, XOR,  >, <, =, >=, <=, !=, isTrue, isFalse, Toggle, Flash, Pulse
    Number of functions 100
    Number of operations 250
    Update frequency 500Hz
    Special functions Wipers, blinkers
    REVIEWS